定量组织速度,Quantitative Tissue Velocity
1)Quantitative Tissue Velocity定量组织速度
英文短句/例句

1.Re-recognization of isovolumic contraction wave with quantitative tissue velocity imaging定量组织速度成像对等容收缩波的再认识
2.Assessment of left ventricular function in children with simple obesity by quantitative tissue velocity imaging and tissue tracking imaging定量组织速度成像和组织追踪成像评价肥胖儿童左心功能
3.Evaluation of left ventricular diastolic function in canine acute myocardial ischemia using velocity vector imaging and quantitative tissue velocity imaging速度向量成像及定量组织速度成像技术评价犬急性心肌缺血状态左心室舒张功能
4.Clinical Study on Asynchrony of Left Ventricular Wall Movement by Quantitative Tissue Velocity Imaging;应用定量组织速度成像技术研究左室运动的协调性
5.To Evaluate the Synchrony and the Function of Ventricles in Bundle Branch Block Patients by Quantitative Tissue Velocity Imaging;定量组织速度成像评价束支传导阻滞患者心室同步性及心功能
6.QTVI Study of Ischemia-related Regional Myocardial Dysfunction in Systolic;定量组织速度成像评估冠心病左室缺血节段心肌收缩功能失常
7.The Research in Left Ventricle Myocardium Movement of CHD by Quantity Tissue Velocity Image Technology;定量组织速度成像技术对冠心病左室心肌运动的研究
8.Evaluation of Heart Function in Patients with RHD Before and After Valve Replacement Operation by Quantitative Tissue Velocity Imaging;定量组织速度成像技术评价风心病人换瓣手术前后心功能
9.Assessment of Global Left Ventricular Systolic and Diastolic Function in Dual-chamber Pacing by Quantitative Tissue Velocity Imaging;应用定量组织速度成像对心脏双腔起搏心功能评价的研究
10.Evaluation of Ventricular Regional Function in Coronary Heart Disease with Quantitative Tissue Velocity Imaging;定量组织速度成像技术对冠心病心肌缺血的研究
11.Assessment of Left Ventricular Function in Hypertension by Quantitative Tissue Velocity Imaging;定量组织速度成像技术评价高血压患者左室功能
12.Study of Carotid Artery Remodeling by Quantitative Tissue Velocity Image in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models不同左室构型高血压病人颈动脉重构的定量组织速度成像研究
13.Assessment of Left Ventricular Myocardial Asynchrony by Quantitative Tissue Velocity Imaging Technology in Patients with Dilated Cardiomyopathy定量组织速度显像技术评价扩张型心肌病左室心肌非同步化运动
14.Evaluation of myocardial functional change in rabbit model with coronary artery atherosclerosis by quantitative tissue velocity imaging超声心动图定量组织速度成像评价动脉粥样硬化兔心肌功能
15.Atrioventricular plane movements under head down tilt position of simulated weightlessness:an analysis by quantitative tissue velocity imaging头低位卧床模拟失重状态下房室平面运动的定量组织速度成像
16.Evaluation of left ventricular function in uremia hemodialysis patients by quantitative tissue velocity imaging定量组织速度成像对尿毒症血液透析患者左心室功能的再评价
17.Assessment of right ventricular function in patients with coronary artery disease using quantitative tissue velocity imaging定量组织速度成像技术评价冠心病患者右心室功能的应用价值
18.Detection of the Left Ventricular Function in Diabetes Mellitus Using Pulsed Wave Tissue Doppler Imaging and Quantitative Tissue Velocity Imaging;脉冲组织多普勒与定量组织速度成像技术对糖尿病患者心脏功能的研究
相关短句/例句

Quantitative tissue velocity imaging定量组织速度成像
1.The quantitative tissue velocity imaging in the diagnosis of coronary artery diseases;定量组织速度成像技术在冠心病诊断方面的应用
2.Assessment of right ventricular diastolic function in patients with essential hypertension by quantitative tissue velocity imaging;定量组织速度成像评价原发性高血压右心室舒张功能
3.Value of quantitative tissue velocity imaging in short effect after coronary artery bypass grafting;定量组织速度成像对冠脉搭桥术短期疗效的评价
3)quantiative tissue velocity i maging QTVI定量组织速度成像(QTVI)
4)Echocardiography Quantitative Tissue Velocity Imaging (QTVI)超声定量组织速度成像
5)Quantitative tissue velocity imaging定量组织速度显像
1.Assessment of left ventricular myocardial contraction and asynchrony in patients with congestive heart failure using quantitative tissue velocity imaging定量组织速度显像评价充血性心力衰竭患者左室收缩及非同步性研究
6)Quantitative tissue velocity imaging定量组织多普勒速度成像
延伸阅读

利用软件方法提高定量包装秤工作速度评价一台定量包装秤的主要技术指标是定量准确度与定量速度,即包装秤的工作效率。然而定量速度与定量准确度是相矛盾的。要想达到较高的准确度与较高效率是很困难的,有时更需要以增加成本为代价。本文通过引入禁止比较判别,分组检测的概念,提出一种在保证准确度的前提下,提高包装秤工作速度的软件控制方法。  一、禁止比较判别法  目前定量包装秤多为两级给料或三级给料方式,其重量可用以下公式表示:  二级W=  三级W=  式中W:实际重量,q:流量,r:物料的比度,t:时间,t0、t1、t2分别为各级给料起、止时间。  实际工作中,前级、末级料流流量比是5~10倍。前级给料主要是用较短的时间加入尽可能多的物料,以缩短称重周期,提高效率。而末级给料则用较长时间加入额定量的5%~10%,以保证称量准确度。从提高速度的角度看,前级料流流量应尽可能大,而且设定值越接近额定值越好;从提高准确度看,末级料流流量应越小越好。然而实际工作过程中,在前级给料结束时,由于物料的冲击,在秤的测量值上造成振荡纹波,实际重量的动态曲线(二级给料)如图1所示。  若提高速度,前级给料设定值应接近末级给料定值,但冲击的波峰可能超过末级给料的设定值,从而造成末级关门。而实际重量并没有超过末级给料设定值,造成误差增大。若要减小误差,传统的方法是减小前级的给料流量,或增加一级给料,以降低冲击力,使冲击的波峰不能超过末级给料值。这样做不是增加了前级给料时间,就是增加了末级给料时间,降低了包装秤的工作效率。为此,通过多次实践,找到了用软件手段解决此问题的方法,即禁止比较判别法。  禁止比较判别法在前级给料结束后,不是马上判别重量是否达到末级给料关门值,而是延时一段时间后,才开始判别,从而使末级判别避开前级给料的冲击在秤上造成的波峰,避免了冲击造成的误差,如图2所示。  采用这样的控制方法,能够使前级给料值更接近末级给料值,也就是增大了前级给料量,相对减小了末级给料量。如果在料流量不变,准确度要求相等条件下,可显著减少末级给料时间,从而缩短整个工作周期,提高工作效率。可以证明,前级、末级料流流量比越大,效果越显著。  二、分组检测法  为保证电子定量包装秤的准确度及其稳定性,现在的称重控制器引入了许多自动控制理论,设置很多自动功能,如零点跟踪功能、零点异常报警功能、自动落差修正功能、超差报警功能等。  但是,所有这些功能,都是以重量为依据的。其中最主要的就是卸料完毕后的空秤值和加料完毕后的满秤值。在动态条件下,准确测量两点的值是比较困难的。传统的作法是每次加料前检测零点值,加料结束后检测满秤值,然后依此作为自动控制的依据。然而定量包装秤是一个动态工作过程,重量数据由动态转变到静态(相对而言)需要一个稳定时间,如果每次都检测静态重量,则势必延长工作周期,降低工作效率。这又是一个保证准确度与提高速度的矛盾。