再热器管,re-heater
1)re-heater再热器管
1.Tubing leakage occurred of a re-heater at Fushun power plant,the relevant case analysis results showed that the leakage was induced by corrosion of the solved oxygen in the water under scale on the tube surface,which then resulted in thinning of the tubing wall and finally in perforation of the tubes.采用化学分析、金相分析,扫描电子显微镜等手段对抚顺发电有限责任公司2号炉低温再热器管泄漏原因进行了分析。
英文短句/例句

1.Characteristics of the Oxide Films on High-Temperature Reheater Pipes Made of 12Cr2MoWVTiB Steel12Cr2MoWVTiB钢高温再热器管氧化膜的特征
2.Causal Investigation into Tertiary Reheater Tube Leakage of 700MW Unit700MW机组三级再热器管子泄漏原因分析
3.The reason analysis of leakage at welding seam of reheater tube supports in 660MW unit660MW机组再热器管间支撑焊缝泄漏原因分析
4.Cause and Measures Taken to Prevent Tube Leakage of High-temperature Reheater for 600 MW Generating Units600MW机组高温再热器管泄漏原因及防范措施
5.Leakage Analysis of Reheater TP347H Tube of a Power Plant某电厂再热器TP347H管泄漏原因分析
6.Analysis to Tube Crack of TP304H Pendant ReheaterTP304H屏式再热器钢管开裂原因分析
7.Crack Analysis of Boiler Pendent Reaheater Tubes Made of SA213-TP304H Steel锅炉屏式再热器TP304H管裂纹分析
8.Analysis and treatment on the blast of HG1025-PM boiler reheater pipesHG1025-PM锅炉再热器常见爆管分析与处理
9.intermediate superheater中间过热器,再热器
10.Theory Analysis and Research on Calculative Method about Overheating Tube Rupture of Superheater and Reheater in Utility Boiler;电站锅炉过热器和再热器超温爆管理论分析与计算方法的研究
11.Research of the Reheater Bursting on 1025t/h boiler in Laicheng Power Plant;莱城电厂1025t/h锅炉再热器爆管研究与实践
12.Research on Spiral Finned Tubes in Application of the Low Temperature Reheater of 670t/h Coal-fired Boiler;螺旋肋片管在670t/h锅炉低温再热器应用的研究
13.A Redesign Method Based on Parameter-sensitivity Analysis for Plate Fin-and-tube Radiators基于参数敏感度分析的管片散热器再设计方法
14.Analysis on Reheater Tube Burst due to Ash Plug of CFB Boiler循环流化床锅炉再热器堵灰爆管的分析与对策
15.600MW Units Reheater Emptuing Pipe Socket Cracking Analysis and Governance600MW机组再热器排空管座开裂原因分析与治理
16.Analysis of Mentals Strength and Creep Life for Case-2180 Tube in 700MW Boiler Ⅲ Reheater700MW锅炉三级再热器Case-2180炉管寿命评估分析
17.Brazed Fin-tube in Boiler High-temperature Reheater Application钎焊鳍片管在锅炉高温再热器上的应用
18.SIMULATION AND ANALYSIS ABOUT WORN-OUT ON CONNECTING PIPE OF LOW-PRESSURE REHEATER FOR A BOILER OF 600 MW UNIT600MW机组锅炉低温再热器连接管磨损的模拟分析
相关短句/例句

reheater bursting再热器爆管
3)small diameter tube of reheater再热器小径管
4)high-temperatue superheater tubes中温再热器管
5)boiler re-heater tube锅炉再热器管
6)reheater tube leakage再热器管泄漏
1.Analysis and solution of reheater tube leakage in boiler No.5 in Shajiao A Power Plant;沙角A电厂5号锅炉再热器管泄漏原因分析及处理
延伸阅读

X线管热容量X线管热容量 放射学术语。X线管允许的最大负荷量。工作时,X线管两极之间要承受极高的电压,并通过一定量电流,高速电子束撞击阳极靶面,将产生大量热能。若超过X线管允许的限度,可导致靶面熔化,造成X线管损坏。X线管的热容量受X线管结构、使用方式及设备总体性能的限制,与曝光时间、管电流、电压、焦点面积及整流方式等有关。