固定污染源,fixed pollution source
1)fixed pollution source固定污染源
1.Methods of determining the sampling position of particula te pollutant from exhaust of fixed pollution source;固定污染源排气中颗粒物采样点位的确定方法
2.Research on dust monitoring of fixed pollution sources固定污染源烟尘监测的研究
3.In order to find the appropriate nitrogen oxides determining methods of the fixed pollution source in Baotou Steel, the competitive test of the fixed potential electrolysis method and N(1-naphty1)-ethylenediamine dihydrochloride spectropho- tometric method is made.为了找出适合包钢实际情况的固定污染源中氮氧化物测试方法,对定电位电解法和盐酸萘乙二胺分光光度法进行了对比试验。
英文短句/例句

1.b. Existing Stationary Sources(二)现有的固定污染源
2.c. New Stationary Sources(三)新的固定污染源
3.Stationary Source Relative Accuracy of CEMS Calculation Template固定污染源CEMS相对准确度计算模板
4.Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary sourceGB/T16157-1996固定污染源排气中颗粒物测定和气态污染物采样方法
5.Methods of determining the sampling position of particula te pollutant from exhaust of fixed pollution source;固定污染源排气中颗粒物采样点位的确定方法
6.The 1970 Act also addressed new stationary sources.1970年的法案也涉及到了新固定污染源的问题。
7.Application of Continuous Emission Monitoring System for Fuel Gas from Stationary Pollution Sources to Incineration of Industrial Hazardous Wastes固定污染源CEMS在工业危险废物焚烧的应用
8.Discussion on Some Technical Problems in Monitoring of Waste Gas from Stationary Sources固定污染源废气监测中的有关问题探讨
9.Continuous Monitoring System for Mercury Emissions from Flue Gas of Stationary Sources固定污染源烟气中汞排放连续监测系统
10.New source performance standards (NSPSs) for stationary sources were to reflect best available control technology, taking into account the costs of compliance.针对固定污染源的《新污染源运行标准》反映出最好的控制技术,并把控制后的成本考虑在内。
11.stationary source emissions-determination of the mass concentration of sulfur dioxide(performance characteristics of automated measuring mathods)固定污染源的排放-二氧化硫浓缩量测定-性能特性自动测量方法
12.stationary source emissions - determination of concentration and mass flow rate of particulate material in gas-carrying ducts - manual gravimetric method固定污染源的排放-气载尘埃颗粒流量和浓度的测定-人工重力法
13.stationary source emissions-determination of asbestos plant emissions (method by fibre count measurement)固定污染源的排放-用纤维计数测量法测定石棉厂的辐射量
14.The term "modification" means any physical change in, or change in the method of operation of, a stationary source which increases the amount of any air pollutant emitted.“改良”这个术语的意思是指固定污染源自身或运行方式的改变。
15.stationary monitoring station for atmospheric pollution大气污染固定监测站
16.The results achieved in the targeted discharge of sources of industrial pollution were consolidated, and a rebound in pollution was prevented.工业污染源达标排放成果巩固,防止了污染反弹;
17.Protocol concerning Land-based Sources of Pollution关于陆源污染的议定书
18.Experimental study on nitrogen removal in micro-polluted water by immobilized microbe technique微生物固定化技术对微污染水源水脱氮的试验研究
相关短句/例句

stationary pollution source固定污染源
1.The composition of continuous emission monitoring system(CEMS) for fuel gas from stationary pollution sources is introduced,and the measurement methods are compared.介绍了固定污染源烟气排放连续监测系统(CEMS)的组成,对测量方法进行了比较。
3)fixed source pollution固定源污染
4)stationary source固定污染源;静止污染源
5)stationary atmospheric pollution source固定大气污染源
1.Based on this case,the analysis is made and the counter measures for improving the regulations on stationary atmospheric pollution source control are presented.通过实例,对企业废气虽然达标排放,但却造成污染扰民问题进行探讨,并通过进一步分析,提出解决完善固定大气污染源控制法规和标准的对策及建议。
6)Atmospheric polluting stationary sources大气固定污染源
延伸阅读

大气污染固定监测站  设在固定位置上对大气质量进行连续自动采样和测定,并对测定的数据进行存贮和传输的设施。它是一个装有采样装置、污染物连续监测仪器、气象参数测定仪器、数据传输及其他辅助装置的实验室。监测站可以是一座建筑物中的一个房间,或者是一座独立的建筑物,也可以是一个可移动的集装箱型或其他轻型的预制房屋。(见彩图)      发展简史  20世纪60年代中期一些国家建立的监测站,所用的连续监测仪器大多采用湿化学方法,一般是有人操作的。70年代初建立的一些监测站,由于连续监测仪器长期运行的可靠性大大提高,以及较普遍地采用干法,一般可以做到无人操作,自动运行,只需定期维护。70年代后期建立的一些监测站,装有专用的微处理机,对连续监测仪器的运行进行控制并化简、存贮、传输数据,使监测站具有智能型功能。    选址  大气污染固定监测站的位置,必须慎重选择。为使采集的大气样品有足够的代表性,通常不应靠近污染源和主要交通干线。监测站水平方向上的障碍物一般不得高于监测站与障碍物水平距离的二分之一,同时应注意地形,以免受局部地区小气候的影响。监测站的面积约为8~20平方米,站体结构应保证室内有适当的温度、湿度等。    设备  监测站内装有大气采样管线,采样头高度一般为3~6米。环境空气经采样管线抽入站内,然后由采样管支线分配至各台监测仪器。管线设计得越短越好,管内压力接近于常压,流量要相当于各台监测仪器从管内抽取样品总量的3~5倍。管子材质的选择要考虑样品在管内通过时损失最小并且便于清洗。采样头的设计应能防尘、防水、防虫。颗粒物监测仪应设有单独的采样管。    仪器和方法  通常站内设有二氧化硫、一氧化碳、氮氧化物、臭氧、总烃(甲烷在外)及颗粒物等污染物的连续监测仪器和风向、风速、温度、湿度等气象参数测定仪器。有些站仅设有其中几种仪器,有些站还有监测其他污染物的仪器。各类仪器的选型和分析方法,应符合国家的规定。对不同的污染物可采取不同的监测方法,如二氧化硫连续监测有紫外脉冲荧光法、气相色谱-火焰光度法、库仑分析法和电导法。一氧化碳连续监测有非分散红外吸收法。氮氧化物连续监测有化学发光法、比色法。臭氧连续监测有化学发光法和紫外吸收光度法。总烃(甲烷在外)连续监测有气相色谱-氢火焰离子化法。颗粒物监测有大容量采样器法、β射线吸收法。风向测定有风旗-滑线电位计法。风速测定有风杯-光电转换器法。温度测定有热敏电阻法。湿度测定有氯化锂传感器法等。在使用监测数据时,应了解各种不同测定方法之间数据的可比性。此外,为了保证安全运行,监测站内还装有可燃气检漏仪和自动灭火或自动断电装置。    数据传输  监测仪器连续测得的污染物浓度模拟信号,经转换器换成数字信号,然后通过电话或无线电发射机定时(如每 5分钟一次)遥传至监测中心。同时在监测站内装有长图记录仪、纸带穿孔机或磁带盒等将实时数据存贮起来,作为原始记录,也可为没有数据通信系统的监测网提供脱机处理形式的数据。在装有专用微处理机的监测站,监测仪器连续测得并经转化的数字信号,首先送入微处理机,经过检误、化简、存贮,然后定时(如每小时一次)传至监测中心。    仪器校正  为了保证测量精度,监测站内的污染物连续监测仪器每日必须用零气和标准气进行零点及跨度校正。仪器的校正方式可在仪器预先设定的周期内定时自动进行,也可接受监测中心的遥控指令随时进行。此外,每隔一段时间还必须进行人工多点线性校正。    监测站正常运行时每年可提供6000小时以上的连续监测数据,对于判断污染源以及污染趋势是很有价值的。70年代中期,中国开始研制大气污染连续自动监测仪器的工作。一些重点城市正在建立研究大气污染固定监测站。